Asymtek TC V3 Spezifikationen Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
3-6 Maintenance
Transmission Chain Tension Adjustment
To adjust the tension of the transmission chain:
1. Turn the power off by moving the Main Switch to the OFF position.
2. Remove the access cover at the output of the conveyor and set aside.
3. Adjust the tension of the transmission chain by turning the chain tightener with a wrench
(Figure 3-4).
Figure 3-4 Transmission Chain Location
4. Turn the power on by moving the Main Switch to the ON position.
5. Before starting a production, activate the conveyor movement and check that the
transmission chain turns without any jerk or noise.
6. Replace the access cover.
Chain
Tightener
Transmission
Chain
Seitenansicht 19